Article: 0  |  Total: 0.00 EUR      10:46 - Tuesday - 24 September - 2019

Infocenter
Changeover switch input of the timer switch
T100HTM with push-button operation
switch input on the telecommunications T100HTM
In addition to the Tele Start a timer or a switch can be installed.

Note:
Timer and button to send different signals to the receiver Telestart
The switching input must be set to the respective control element
Factory is the switching input of the telephone set receiver to start timer
For the parallel operation of the tele-offs and a further control element, a slot on the ESV adapter cable is available.

timer
With the switch (by pressing the button immediately to heat or power by programming) shall start the timer of the Tele Plus a continuous signal during the entire duty cycle.
By switching off (by pressing the button immediately turn off heat or by limiting the duration timer) is withdrawn the plus signal and the heater is turned off.

switch
When you turn on and off switch is replaced with the Telestart receiver plus a short signal.
Thus the Telestart recognizes this signal, the signal input must be set to switch.
The signal input is not switched to push-button switches the heater is not paid, but running in the follow-up and go out.

changeover switch input of the timer switch
1. Fuse 1A (black) from the heater, remove the fuse holder (voltage interruption).
2. At least wait 5 seconds.
3. Briefly press fuse in fuse holder and heating equipment began within 5 seconds of button 1x.
4. Conversion completed.


changeover switch input from sensors on timer
1. Fuse 1A (black) from the heater, remove the fuse holder (voltage interruption).
2. At least wait 5 seconds.
3. Heating equipment uses heat to fuse and fuse holder within 2 seconds, press C to activate the timer briefly (display backlight is lit).
4. Just 10 seconds after pressing button Sofortheizen (display light goes out).
5. Conversion completed.

Key Numbers Search ?

HSN TSN

Parts Finder


 


Parse Time: 0.141s